Summary:
File-Print Text or Luminaire Schedule - Coordinates and/or aiming points in 'Expanded Luminaire Summary' may not match coordinates in 'Luminaire Location Summary' or in Modify-Luminaire-Edit dialog.
More Information:
The expanded summary breaks arrangements into individual locations and shows coordinates with arm length and offset applied (applies to single arrangements with arm length also).
The expanded summary calculates the aiming point based on the aiming angles. If the tilt angle is >=90, the program assumes and arbitrary Z for the aiming points (2 x MH) and calculates the corresponding X and Y aiming point. This is done to handle all cases (i.e. - exploding groups and arrangements).
If only have single luminaire locations (no arrangements or groups), it is not recommended to use the Expanded Luminaire Summary (use the Luminaire Location Summary schedule instead).
Status:
By design
Applies To:
AGI32 - All versions